Genuine products · Delivery across Egypt
0
0
0
Uniview TIC600-S Automatic Thermal Temperature Measurement and Screening System (384 × 288, 3–10 m)

Uniview TIC600-S Automatic Thermal Temperature Measurement and Screening System (384 × 288, 3–10 m)

15 people are viewing this right now

Available in these locations:

Egypt

Price on request — contact us for a quotation

The Uniview TIC600-S is an automatic thermal temperature measurement and screening system for fast, non-contact screening of multiple people at a distance of 3 to 10 meters.

It pairs a 384 × 288 uncooled thermal camera with a 2MP visible-light camera and a reference blackbody, achieving temperature measurement accuracy of ±0.3 °C. Visible and thermal images are displayed side by side, and the system automatically raises an alarm and takes a snapshot when a fever target is detected.

Delivered with tripods, blackbody and PC software, the TIC600-S is suited to high-traffic entrances such as airports, hospitals, factories, malls and government buildings in Egypt.

Description

The TIC600-S is designed for screening crowds rather than individuals. Its non-contact plane surface array measurement scans everyone within the field of view in real time, allowing many people to be screened per minute without stopping the flow of traffic.

Thermal and Visible Dual Imaging

The thermal camera uses an uncooled focal plane array with 384 × 288 resolution, 25 μm pixels, NETD of 60 mK or less and an 18 mm F1.0 lens (25° × 19° field of view). A 1/1.8" 1080P visible camera with a 3.8–16 mm lens and 120 dB WDR provides a clear color image for identifying people.

Blackbody-Calibrated Accuracy

A reference blackbody (±0.2 °C single-point accuracy) is placed in the scene to continuously calibrate the thermal camera, giving temperature measurement accuracy of ±0.3 °C or better for body temperatures in the 32–42 °C range.

Automatic Alarm and Evidence Capture

When a person exceeding the alarm threshold is detected, the system triggers a multi-point abnormal temperature alarm and automatically captures images for post-event review. Historical alarm records can be searched in the PC software.

  • Real-time multi-target temperature measurement
  • Automatic snapshot on fever alarm
  • Automatic body and surface temperature calibration
  • Historical alarm record query

Deployment Requirements

The system is intended for indoor, windless environments with an ambient temperature of 16–32 °C. It requires a Windows 10 64-bit PC (Intel i5 or better, 8 GB RAM) with a network port to run the screening software.

Key Features

  • Non-contact plane surface array temperature measurement
  • Screening distance 3–10 m
  • Real-time multi-person screening
  • 384 × 288 uncooled thermal sensor
  • NETD ≤60 mK
  • 18 mm F1.0 thermal lens, 25° × 19° FOV
  • 2MP 1080P visible camera, 3.8–16 mm lens
  • 120 dB WDR on visible camera
  • Simultaneous visible and thermal display
  • Blackbody calibration
  • Measurement accuracy ±0.3 °C
  • Target range 32–42 °C
  • Automatic fever alarm
  • Automatic snapshot on alarm
  • Historical alarm query
  • Tripods and PC software included

Technical Specifications

Brand Uniview (UNV)
Model TIC600-S
Product Type Automatic Thermal Temperature Measurement and Screening System
Measurement Method Non-contact plane surface array temperature measurement
Detection Distance 3–10 m
Measurement Accuracy ≤ ±0.3 °C (with blackbody)
Target Temperature Range 32–42 °C
Ambient Temperature Range 16–32 °C
Thermal Sensor Uncooled focal plane array (uFPA)
Thermal Resolution 384 × 288
Pixel Size 25 μm
NETD ≤60 mK
Spectral Range 8–14 μm
Thermal Lens 18 mm, F1.0
Thermal FOV (H × V) 25° × 19°
Thermal Frame Rate 25 fps
Visible Sensor 1/1.8" progressive scan CMOS
Visible Resolution 1920 × 1080 @ up to 30 fps
Visible Lens 3.8–16 mm, manual focus, F1.6
Visible WDR 120 dB
Visible Edge Storage MicroSD, up to 256 GB
Blackbody Accuracy ±0.2 °C (single point)
Blackbody Stability ±(0.1–0.2) °C / 30 min
Blackbody Radiation Area φ70 mm
Blackbody Power 220 V AC, 50 Hz, 60 W
Alarm Multi-point abnormal temperature alarm, automatic capture
Network Interface RJ45
Camera Power DC 12 V, ≤15 W
Camera Weight <5 kg
Humidity ≤90% RH (non-condensing)
PC Requirements Intel i5 or above, 8 GB RAM, Windows 10 64-bit
Specs Source Uniview TIC600 Automatic Thermal Temperature Measurement and Screening System datasheet V1.1 (Zhejiang Uniview Technologies), hosted by Ellipse Security

Main Benefits

Screen Crowds Without Queues

Measures multiple people at 3–10 m in real time without stopping traffic.

No Physical Contact

Non-contact screening reduces cross-infection risk for staff and visitors.

Calibrated Accuracy

The reference blackbody keeps measurement accuracy within ±0.3 °C.

Clear Identification

The visible camera shows exactly who triggered an alarm.

Automatic Evidence

Snapshots are taken automatically for every fever alarm and can be reviewed later.

Complete Kit

Thermal camera, blackbody, tripods and software are supplied together.

Recommended Uses

  • Airports and train stations
  • Hospitals
  • Factories and industrial sites
  • Shopping malls
  • Government buildings
  • Office towers
  • Schools and universities
  • Stadiums and event venues
  • Hotels
  • Banks

Package Contents

  • 1 × Thermography camera
  • 1 × Blackbody
  • 2 × Tripods
  • 1 × Power adapter
  • PC screening software

Reviews

There are no reviews yet.

Be the first to review “Uniview TIC600-S Automatic Thermal Temperature Measurement and Screening System (384 × 288, 3–10 m)”

Your email address will not be published. Required fields are marked *

Uniview TIC600-S Automatic Thermal Temperature Measurement and Screening System (384 × 288, 3–10 m)

Uniview TIC600-S Automatic Thermal Temperature Measurement and Screening System (384 × 288, 3–10 m)

Loading...

Choose your Delivery Location

Enter your address and we will specify the offer for your area.